Tạp chí Tim mạch học Việt Nam

Article detail

Article detail description

Home
NGHIÊN CỨU LÂM SÀNG Issue: Số 71 - 2015 PHẪU THUẬT TIM MẠCH

Study of role of mixed venous oxygen saturation measuarement in hemodynamic monitoring of high-risk cardiac surgical patients

Published: October 18, 2015
Views: 52

Abstract

Background: With more and more hospitals establishing and/or expanding their open-heart surgery programs, it is important for clinicians to have a clear understanding of the methods used for patient monitoring. One of most versatile and probably most misunderstood is mixed venous oxygen saturation (SvO2) and how it relates to cardiac function, oxygen delivery (DO2) and oxygen consumption (VO2). Object: we present the study of application of mixed venous oxygen saturation measurement and the evaluation of role of this technique in hemodynamic monitoring of high-risk cardiac surgical patients. Material and Method: 60 patients undergoing elective cardiac surgery to a protocol involving the administration of intravenous fluid and inotropic therapy to attain a target SvO2 of at least 70% in first 8h after surgery. Dobutamine was administered in dose of up to 15µg/kg/min where the target SvO2 was not achieved with intravenous fluid alone. Control group patients were administered intravenous fluid and dobutamine to meet goals for pulmonary artery occlusion pressure, cardiac index, arterial pressure, and hematocrit. Results: SvO2 was similar in two groups at baseline (67±6%), but there were greater improvements in SvO2 in the SvO2 group (control group 69±5% vs. SvO2 group 71±4%; p<0,001). SvO2 guided therapy was associated with a reduction in both ICU stay (29,23±7,82 vs. 40,27 ± 9,04 hours; p<0,001) and the number of patients developing complications. Conclusion: Hemodynamic therapy to attain a target value for SvO2 is more appropriate in this context as confounding causes of decreased venous saturation are minimized. This treatment is possible after cardiac surgery where postoperative intensive care admission is a standard of care.

Keywords
Mixed venous oxygen saturation SvO2 cardiac surgery hemodynamic monitoring

References

1.
Eagle K. A., Brundage B. H., Chaitman, BR et al (2011). Guidlines for perioperative cardiovascular evaluation for cardiac surgery. Circulation; 93: 1278-1317 and JACC, 27: 910-948
2.
Edward Lifesciences (2011). Understanding continuous mixed venous oxygen saturation (SvO2) monitoring with the Swan-Ganz oximetry TD System. Edward Critical Care Education 3rd Edition; 1161 - 11/00 - CC.
3.
ESCAPE Investigators and ESCAPE Study Coordinators (2011). Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness. The ESCAPE trial, Journal of American Medical Association, pp. 1625 - 1633.
4.
Richard C., Monet X., Anguel N., Teboul J. L. (2012). Évaluation d'intérêt d'un outil de monitoring : le cathéter artériel pulmonaire. Insuffisance Circulatoire Aigue, © 2012 Elservier Masson SAS.
5.
Shoemaker W. C., Appel P. L., Kram H. B., Waxman K. and Lee T. S. (2010). Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. Official publication of the American College of Chest phisicians; 1176 - 1186.

Tác giả

Huỳnh Văn Minh: Trường Đại học Y Dược, Đại học Huế; Đoàn Đức Hoằng: Bệnh viện Trung ương Huế; Đặng Quốc Kha: Bệnh viện Trung ương Huế; Nguyễn Đức Thành: Bệnh viện Trung ương Huế; Cao Đức Kim Tuyến: Bệnh viện Trung ương Huế;
Study of role of mixed venous oxygen saturation measuarement in hemodynamic monitoring of high-risk cardiac surgical patients

Files

Article Views52
Document Views0
Downloads11
Section NGHIÊN CỨU LÂM SÀNG
Category PHẪU THUẬT TIM MẠCH
Pages 21-29
Copyright Holder 2015 Tạp chí Tim mạch học Việt Nam