Abstract
Background: With more and more hospitals establishing and/or expanding their open-heart surgery programs, it is important for clinicians to have a clear understanding of the methods used for patient monitoring. One of most versatile and probably most misunderstood is mixed venous oxygen saturation (SvO2) and how it relates to cardiac function, oxygen delivery (DO2) and oxygen consumption (VO2). Object: we present the study of application of mixed venous oxygen saturation measurement and the evaluation of role of this technique in hemodynamic monitoring of high-risk cardiac surgical patients. Material and Method: 60 patients undergoing elective cardiac surgery to a protocol involving the administration of intravenous fluid and inotropic therapy to attain a target SvO2 of at least 70% in first 8h after surgery. Dobutamine was administered in dose of up to 15µg/kg/min where the target SvO2 was not achieved with intravenous fluid alone. Control group patients were administered intravenous fluid and dobutamine to meet goals for pulmonary artery occlusion pressure, cardiac index, arterial pressure, and hematocrit. Results: SvO2 was similar in two groups at baseline (67±6%), but there were greater improvements in SvO2 in the SvO2 group (control group 69±5% vs. SvO2 group 71±4%; p<0,001). SvO2 guided therapy was associated with a reduction in both ICU stay (29,23±7,82 vs. 40,27 ± 9,04 hours; p<0,001) and the number of patients developing complications. Conclusion: Hemodynamic therapy to attain a target value for SvO2 is more appropriate in this context as confounding causes of decreased venous saturation are minimized. This treatment is possible after cardiac surgery where postoperative intensive care admission is a standard of care.