Abstract
In chronic heart failure patients, the ejection fraction index (EF) is clinically considered the most important. However, it is believed that torsional parameters are not less important than those in assessment of left ventricular function. Speckle tracking echocardiography is a new method with high accuracy to assess the torsional motion of the left ventricle which can be applied clinically. Objective: Assessing the changes of left ventricular torsion and its relationship with other 2D echocardiographic parameters in chronic systolic dysfunction patients. Method: 41 healthy subjects and 70 patients with left ventricular systolic dysfunction were included in the study. All patients were examined, surface ECG performed and online echocardiography recorded. After this, the recorded material was analyzed offline with ECHOPAC 112 software (GE, USA). Result: All the torsional parameters including AR, ARV, BR, BRV, T, TV decreased in the heart failure groups in comparison with the healthy group. Similarly, the time to peak torsional degree and velocity were longer in the heart failure group compared with the healthy group. In the group of patients with heart failure due to previous MI, the decline of torsion degree was maximal (T=6.3 degree), and due to hypertension was minimal (T=8.1 degree). Patients with higher level of heart failure (NYHA) had more torsional decline. Torsion correlated well with the EF index (r=0.83) and inversely with Dd (r=-0.72). Conclusion: Torsion is a pivotal parameter in assessment of left ventricular function and correlates well with ejection fraction index (EF) and inversely with left ventricular diastolic diameter (Dd).