Abstract
Objective: We investigated the immediate benefits of cardiac resynchronization therapy (CRT). Method: 52 patients were implanted CRT devices at the Vietnam National Heart Institute from 1/2008 to 10/2011. The immediate changes in clinical and echocardiographic parameters after CRT implantation were assessed. Results: Our data show a significant clinical benefit of CRT (NYHA change from 3,67± 0,47 to 2,62±0,54; p<0,001), decreased the mitral regurgitation area jet (from 9,10± 4,80 cm2 to 6,62±4,29 cm2; p <0,001), left ventricular end-diastolic volume (from 225,30±94,76 ml to 186,30±75,11 ml; p=0,001), left ventricular end-systolic volume (from 299,59±113,34 ml to 258,59±93,86 ml, p=0,01), increased stroke volume (from 51,73±8,51 ml to 57,34±7,31 ml; p <0,001), cardiac output (from 2,36±1,02 l/min to 3,29±0,73 l/min; p=0,039). Conclusion: CRT has the acute benefits in clinical and hemodynamic improvements.